Gas Control System

The detector gas used in the PPACS is instrument grade isobutane at a pressure of 4 torr. There are two gas volumes, one for each hemisphere of the detector, and 10 PPACs are housed within each volume. The circulation and pressure of the isobutane for each volume is controlled by an independent gas handling system. A schematic of the gas handling systems is shown in Figure 10. The pressure difference across of the pressure window is monitored by a 10 torr MKS 233B differential Baratron gauge, and this pressure difference is maintained by a MKS 250 controller and associated valve. The absolute pressure is monitored by a 1000 torr Baratron gauge while the flow rate is monitored by a MKS 1259 mass flow meter.

  
Figure 10: The CHICO gas control system.